ZJ-6250
silicone gel

ZJ-6250 is a medium viscosity, two-component, 1:1 mixed liquid flow silicone gel, which can be cured at room temperature or by heating. Applied to encapsulate electronic precision electrical circuits and hybrid circuits, solar cells, sensors, high-power rectifiers, IGBT modules, and electronic components of optoelectronic equipment in automobiles, providing waterproof, moisture-proof, dustproof, moisture-proof, shockproof, and insulation protection for electronic components and assemblies。

Product features

1. Two component, 1:1 mixture

2. Addition curing without by-products

3. Medium viscosity, fast curing

4. Transparent and soft, with self-healing properties

5. High transmittance, yellow becomes smaller

Product parameters
Main parameters of ZJ-6250
Physical property items Unit Test method Characterization results
Before curing

Viscosity(mpa.s)

A

GB/T 2794

560

B

GB/T 2794

1002

Density(g/cm3)

A

GB/T 13354

0.97

B

GB/T 13354

0.97

Mixing ratio

A:B

/

1:1

Mixed densityg/cm3)

A+B

GB/T 13354

0.97

Operational time after mixing/25℃(h)

A+B

GB/T 7123

1

Lnitial gel time/25℃(h)

A+B

/

6

Curing conditions(℃×min)

A+B

/

120×30

After curing

Density/25℃(g/cm3)

GB/T 13354

0.98

Penetration(mm/10)

GBT 4509-2010

350

Dielectric constant

GB/T1693

2.7

Volume resistivity(Ω·cm)

GB/T 1692

1015

Dielectric strength(KV/mm)

GB/T 1695

15

Refractive index/23℃

ABBE

1.405

Transmittance(%)

UV-VIS

99

Flame retardancy

UL

94HB

The data in the table is for reference only, please refer to the measured data
Operation and Safety
  • Before use, thoroughly mix components A and B in a 1:1 ratio. Stir for 5 minutes. It is recommended to use it after 5-10 minutes of vacuuming at -0.09MPa~-0.08MPa
  • Temperature and curing time: 25 ℃, no flow starting from 120 minutes; Fully cure at 120 ℃ for 30 minutes.
  • The mixed adhesive should be sealed, stored, and used up within a safe operating period, otherwise it will slowly solidify and cause waste.
  • The curing speed of the adhesive is related to temperature to a certain extent, and curing will be slower at low temperatures.
  • This product is not a hazardous material, but do not enter or eye contact. If accidentally splashed, rinse with plenty of water.
  • The A and B components of the colloid must be sealed and stored to prevent leakage during transportation!
  • During the vulcanization process, this product should avoid contact with organic compounds such as N, P, S, ionic compounds containing heavy metals such as Sn, Pb, Hg, Sb, Bi, As, as well as organic compounds containing unsaturated groups such as acetylene groups. Otherwise, it may cause poor adhesive curing. Therefore, compatibility testing between silicone rubber and the substrate should be conducted first before use。
Color and packaging

A group of 20Kg for component A and 20Kg for component B (small bucket),

Or a set of A component 200Kg and B component 200Kg (large barrel)

Storage and expiration date

Store in a dry place for a storage period of 12 months. If it expires, it needs to be retested and can be reused after passing the inspection.

This type of product belongs to non hazardous goods and can be transported as general chemicals.